ADTO News
-
How to Connect the Standard Tubes Of Ringlock Scaffolding in the Project
Ringlock scaffold of vertical poling socket means has two kinds, one kind is the internal connection, is a kind of outer sleeve connection, common length for the vertical poling are 1 meter, 1.5 meters, 2 meters, 2.5 meters and 3 meters, each vertical bar at the top of the 100 mm reserved, reserved at the bottom of the 400 mm, with ringlock scaffolding faceplate spacing, it ensures that all products are common length. So the socket after each lap length is 500 mm in a
2017-07-13 -
What Are the Usage of Ringlock Scaffolding Tubes in the Project
Ringlock scaffolding provider said lifting scaffold is through the AD hoc bearing point, the use of sling suspension hanger or hanging basket for building decorate a scaffold. The following is the main part of: First of all, the scaffold structure and bridge girder workbench bridge is the same, it is mainly used for industrial buildings or frame structure building enclosure wall masonry. Steel scaffolding planks provider said second, bearing system is made up of pick and sling. Layout
2017-07-12 -
Is that Real For the Ringlock Scaffolding to Save Time and Cost
Believe many construction units used the traditional scaffold will have such experience, more or less traditional scaffolding or turns less, or the construction efficiency is low, or amount is larger, severe resource waste, or safety reliability is low, in short, a lot of problems. Believe many construction units used the traditional scaffold will have such experience, more or less traditional scaffolding or turns less, or the construction efficiency is low, or amount is larger, severe resource
2017-07-12 -
What Are the Requirement Standard to Build Ringlock Scaffolding Project
Socket type ringlock scaffolding, specification 1. Important scaffold must formulate the construction plan, when it is necessary to develop safety guarantee measures. 2. The height more than 25 m scaffold fastener type steel pipe scaffold must be adopted, the stem scaffold height should be controlled within 50 m; The scaffold height more than 50 m
2017-07-11 -
How Many Steps Are There to Building the Rinlgock Scaffolding in the Project
A, ringlock type scaffold erection sequence and steps 1, in accordance with the site and layout size, put the adjustable base, and the adjustable base nut to roughly the same level; 2, install the vertical pole erected on the adjustable base, and in the same way the installation adjacent to a vertical rod; 3, will correspond to the span length of rail hooking in installed good promulgation and between ringlock.
2017-07-11 -
Ringlock Scaffolding to be Safer and More Efficient in the Construction Project
Ringlock scaffolding, more safe, efficient, ringlock scaffold poling using Q345 grade steel malleable cast, than the original level of Q235 steel has higher strength and bearing capacity of single stud bigger, up to 20 tons. Unique ringlock design, can make the link between the implementation direction more stable connection, can satisfy the demands of scaffolding, all kinds of connections. With scaffolding steel is more than the traditional bamboo springboard has
2017-07-10 -
Why Can the Ringlock Scaffolding Save Your Time And Energy
All kinds of ringlock scaffolding, cuplock ringlock scaffolding, scaffolding accessories products, all products comply with the corresponding production standards, quality reliable, guarantee can satisfy the using demand of the customers. Ringlock scaffold quick assembly, operation bento, save cost, with less dosage, light weight, operators can double local assembling. Take down the fee, freight, rent and maintenance fee accordingly to save city, general environment can save 30%.Ringlock scaffold can better save cost, higher efficiency, of course ringlock scaffold system
2017-07-10 -
The Frame Body and Project Structure Connection of the Ringlock Scaffolding
Ringlock scaffolding structures, standard frame body and Rachel engineering structure 1, ringlock scaffolding in 7 meters high, can use set behind support method to maintain the stability of the ringlock scaffolding, when set up more than 7 meters high inconvenience set behind hold, should be for lap and engineering. (1) the ringlock scaffolding and engineering content lap can not only prevent because of the wind load and accident happened or inward to flare, and can be used as a frame in the middle of the
2017-07-09 -
Who Knows What Tips Shall Be Paid Attention to When Building ringlock Scaffolding
The so-called ringlock scaffolding is refers to the socket type button scaffold, matters needing attention are as follows: 1, buckle with socket type ringlock type steel tube scaffold erection of double-row scaffold, the erection height should not be greater than 24 m. Can choose according to the requirement frame body geometry size, the adjacent level interval appropriate chooses 2 m, poling longitudinal spacing should be 1.5 m or 1.8 m, and should not be greater than 2. 1 m, poling horizontal
2017-07-09 -
Tell You More About the Construction of Scaffolding in the Project
A, scaffolding material and specifications (1) the material of steel pipe and specifications Generally adopt appropriate GBT00 ordinary carbon structural technical conditions of technical requirements of A3 steel, flat and smooth appearance, no crack, delamination, distorted, make hole section and is less than 0.5 mm steel pipe corrosion degree, must have the manufacturer's quality certificate or rental unit quality assurance certificate.
2017-07-06 -
More Info for the Structural Requirements of Scaffolding Projects
1, the basic structure Fastener steel pipe scaffold has a single row and double bent in two, double row fastener type steel pipe scaffold erection height should not be more than 50 m, horizontal stud spacing of 1.5 m, longitudinal vertical pole spacing of 1.5 m or less, small bar spacing of 1.0 m or less, the ledger interval 1.6 to 1.8 m, small bar to hang a wall 0.40 m long. 2.Demand, structure
2017-07-06 -
What Are the Requirements of Building the Scaffolding Tubes in the Project
1, steel fasteners, scaffolding, should be paid attention to in the foundation level solid, and set up base plate, and have reliable drainage measures to prevent the water soak a foundation. 2, according to the situation of rod set up the wall and load size, the commonly used open type double row scaffolding rod. Horizontal spacing generally 1.05 ~ 1.55 m, building scaffolding interval is 1.20 ~ 1.35 m, commonly decoration or building, decoration and scaffolding generally
2017-07-05 -
Technical Requirements on the Erection of Scaffolding Ringlock
Ringlock scaffolding and scaffolding used materials and the erection method is the same as ordinary steel pipe fastener scaffold, specific requirements are as follows: 1, poling: ≯ 2 m, horizontal stud spacing interval ≯ 1.8 m, the ground should be leveling to consolidate vertical pole into the ground 30 ~ 50 cm, would not be buried, stud should pad under sleepers and added rod sweeps the floor. Step 2, bar: lateral horizontal tie from ≯ 1.8 m, the operational layer of ledger spacing ≯ 40
2017-07-05 -
Requirements on the Usage and Building of Scaffolding on the Site
In strict accordance with the provisions of the structure size of the erection, the vertical deviation control good poling and rail horizontal deviation; Stud must be vertically on a mat, the cushion thickness of concrete block or not less than 50 mm boards. Should use docking fastener steel pipe connection. Steel pipe scaffold should be take into double strut and in the furnace or masonry with wedge stuck between fixed. Build-up to timely in the process of setting diagonal
2017-07-04 -
What Rules Are there When Choosing the Scaffolding Material Before Building
1. Fastener quality assurance materials should be complete, enter the site shall be carried out after sampling the second interview, technical functions should fit the rules of the steel pipe scaffold fastener GB15831, should choose one by one before use, have crack, deformation, the bolt slide wire to stop using. 2. The welded pipe diameter should be 48-51 mm, wall thickness 3-3.5 mm, length to 4-6.5-2.8 m and 2.1 m, there are serious rust, bending, crack, damage may not be used.
2017-07-04