ADTO News
Key points for the calculation of steel tubular scaffolding with couplers
Ledger: strength and rigidity
Connecting scaffolding coupler: anti-skid capacity and load-bearing capacity
Standing tube: stability ratio
Tie member: strength, stability and connection strength
Style steel: cantilevered beam calculation
Regular calculation standards
Safety technological codes of steel tubular scaffolding with girder coupler scaffolding for the project construction; codes of the building structure load and the design code of the steel structure.
e.g. the standard value of the self-weight working load is 39.7 N/M if the quality of the steel tube with a size of 48.3*3.6m is 3.97N/M.
variable load: which can be neglected during the construction if there is any change even if compared with an average value, including the weight of the working staff and equipment as well as the wind load and elements including the scaffolding coupler.
How to design the working load value- multiply the standard working load value by the partial coefficient; one of the permanent working load is 1.2 and that of the variable working load is 1.4. Composite coefficient of two or above variable working load is 0.9 ( wind with uniform distributed the working load.)