1, even the wall should be close to the master node set, the distance of the deviation from the master node should not be greater than 300 mm, when greater than 300 mm, should strengthen the measures. When even the wall piece near interval of 1/2 scaffolding poling, must be adjusted.
2, even the wall parts should start with the first step in the bottom longitudinal bar setting, when the registry settings have difficulty, other reliable fixation measures should be adopted. Even the wall a appropriate arrangement, square, rectangular arrangement may be adopted.
3, even the wall should be adopted rigid wall parts connected to the building.
4, even the wall pole appropriate level Settings, when not level Settings, connected to the scaffold should be at the end of the downward inclined connection, should not be connected by oblique upward.
5, even the wall spacing should accord with the requirement of special construction scheme, horizontal direction should not be greater than 3 across, vertical direction should not be greater than 3 step, also should not be greater than 4 m (frame body height for more than 50 m should not be greater than 2). Even the wall piece on top of the building corner within 1 m and within 800 mm should be encrypted.
6, one word, the ends of the open mouth of scaffolding must be set even wall, the wall of a vertical spacing should not be greater than the height of the building, should not greater than 4 m or 2 step;
7, the scaffolding should be set-up cooperated with construction schedule should be not more than a build-up adjacent wall for more than a step or two.